LET US HELP YOU GROW
Display indication (Only Dimlux Expert 315W + 630W)
Each Dimlux fixture has a self diagnosis system. The display on each unit shows error and status info.

Status |
|
F-Flash = Soft off |
The ballast is off because the dim button is on soft-off. |
F-on = On-DB |
The ballast is on, no Maxi Controller detected. |
A-Flash = Off remote |
The ballast is off by Maxi Controller. |
A-on = on remote |
The ballast is on by Maxi Controller. |
1-strobo = Igniting |
The ballast is igniting the lamp. |
Error |
|
2-On = HVP |
The input voltage is too high. |
3-On = LVP |
The input voltage is too low. |
4-On = HTP |
The ballast is too hot. |
5-On = Open |
Open contact or lamp failure. |
6-On = Short |
Short in lamp circuit or lamp failure. |
7-On = EOL |
End-of-life. Lamp surpassed it’s service life. Maximum power connot be attained anymore.* |